This site uses cookies. By continuing to use the site, we agree that you agree to the use of cookies. Learn more about them and learn about our privacy policy here

SCALING AND CORROSION PROTECTION SYSTEM

Scaling and corrosion protection system

Protection against scale and its harmful effects.
Protection of the water supply system and appliances in the home or industry related to scale. Hydro Magnetic Systems for neutralization and cleaning of limestone, scale and their derivatives prevents the formation of scale and removes existing deposits on the network.
Short description
manufacturer's warranty from 25 to 50 years. (depending on the model)
The hydromagnetic system we offer changes the hardness of the water passing through it by preventing the formation of scale and removes existing deposits on the network. The neutralizer acts through a strong cyclic magnetic field created by modern high-energy magnets. Under the influence of this field the physical properties of water change and as a result the salts of calcium and magnesium contained in it change their ability to be deposited in the form of dense stone. swimming pools, cold and hot water supply networks, steam and water boilers, boilers and heat exchangers, industrial cooling and humidification systems.
The neutralizer has the following technical parameters:
• the main system is the magnetic material neodymium-iron-boron (Nd – Fe – B);
• the magnetic energy of the core material is (HV)> 260 kJ / m3;
• the residual magnetic induction of the core is 1.15 - 1.25 T;
• the radial component of the magnetic induction near the inner wall of the housing is not less than 0.2 T;
• maximum water pressure - 0.8 MPa, upon prior request - up to 1.6 MPa;
• velocity of the water flowing through the HMS - 0.5 - 4.0 m / s.


The various variants of the hydro magnetic anti-postponing systems are suitable both domestic and heavy chemical premises, plant systems, heating systems with hot or cold water, and transmission networks in blocks, entrances, separate apartments . GUARANTEED CLEANING OF THE BOILER SYSTEM WITHIN 30 DAYS UNDER NORMAL OPERATING REGIME.
The scale falls, HMS does not allow the formation of new scale, and your appliances and piping are cleaned to a state - NEW !!!
Hydro magnetic system helps to extend the life and service life of all equipment.As in the home these are, water heater, washing machine, dishwasher, faucets, showers, pipes. After washing with water that has passed through the HMS, the scale is decomposed by trays, pots, stoves and everything that has been in contact with water.
The hydro-magnetic system against deposits and limestone also protects the human body.
OUR CLIENTS ARE A NUMBER OF ENTERPRISES. AS OUR MAIN PRIDE ARE THE INSTALLED HYDRO-MAGNETIC SYSTEMS, IN THE CLOSED CYCLE OF ENTERPRISES - SODI DEVNYA. AFTER THE INSTALLATION, THE COSTS IN THE COMPANY FOR CLEANING BOILER AND REPAIRS DAMAGE TO THE DEPRECIATION OF THE PIPELINE SYSTEM ARE REDUCED TO ABSOLUTE. THE PIPES THAT HAVE NEEDED WEEKLY CLEANING UNTIL THIS MOMENT TODAY RELY ON HYDRO MAGNETIC SYSTEMS THAT SAVE A HUGE MONEY RESOURCE.
PROTECTS YOUR WHOLE HOME FROM BOILER AND DEPOSITS, PROTECTS THE WATER SUPPLY AS WELL AS ALL VESSELS FOR USE
The neutralizers are subdivided into household and industrial series:
The household series is produced in threaded versions and is designed for water consumption from 0.08 to 2.0 cubic meters per hour (respectively for pipelines with a diameter of 15-20 mm) (½ ”- ¾”). The housing material is stainless steel.
The industrial series is produced in a flange version. It is designed for water consumption from 0.2 to 1100 cubic meters / hour (respectively for pipelines with a diameter of 15 - 500 mm). The housing material for Du 15, 20 and 25 mm is stainless steel. The housings of Du 32 mm and larger are made of high carbon steel.
The HMS hardness neutralizer provides:
-prevention of scale formation;
-separation of existing scale;
- improving heat dissipation;
- reduction of fuel and electricity consumption;
- increasing the shelf life of the equipment.
The neutralizer is easy to install, reliable and long-lasting, requires absolutely no maintenance and pays off quickly. There are no costs for electricity, materials and consumables with a manufacturer's warranty of 25 to 50 years.

Delivery time of HMS to the client - up to 3 days.
For quantities 60% prepayment.
Time for production of systems from Du 125 mm and bigger - from 2 to 4 weeks.
Limestone is a rock composed mainly of calcium carbonate. Waters with a high content of this element are called - hard. When such water is heated to temperatures above 50 C, the limestone is deposited on the aquifers. These deposits are known as - scale or scale. This leads to wear, narrowing of leaking currents and clogging. If it is not treated for drinking purposes, the water can be treated with preparations to reduce the lime content.
Limestone in the water prevails everywhere and causes the accumulation of so-called scale on the walls of the pipes, around the heaters and other parts of the machines and the water supply network. Decreased productivity and increased electricity costs are a consequence of this. The service life of the installation related to the water system will also be affected.
The method of Hydro Magnetic System, against deposits and scale is both effective and environmentally friendly - without chemical additives that change the taste and quality of water. Also, the amount of detergents in machines and appliances can be reduced by an average of about 25%, as a result of the lower surface tension of the water.

Applications:
Residential buildings;
Hotels;
Swimming pools;
Industrial production;
Factories and plants;
Boiler rooms;

--------------------------------------------------- -


consequences of scale - https://www.youtube.com/watch?v=WB0uPkLQOWg&feature=youtu.be
The problem: scale and corrosion
Calculus and corrosion have always been a huge problem for industry because they increase production costs. Calcium, magnesium and carbonate ions form solid crystal-like deposits, the amount of which increases in proportion to temperature. This leads to the formation of a layer of scale in the pipes, premature deterioration of the characteristics of the equipment, damage to machinery and finally reduced efficiency in production. In addition, the oxygen contained in the water activates the corrosion of the entire equipment and machinery.
Consequences:
Circulating cooling systems (eg cooling towers) must be descaled chemically, which is a waste of time and money.
Tubular heat exchangers must be chemically cleaned, and the plates of plastic heat exchangers must in most cases be replaced.
Combi ovens accumulate scale at high temperatures.
Vacuum and centrifugal pumps accumulate scale and this greatly shortens their service life.
Calculus and corrosion products accumulate in the pipelines, causing accidents and flood conditions.
Showers, toilets, dishwashers and washing systems, hot water boilers and fittings accumulate scale deposits and the heating elements must be cleaned or replaced periodically.
Maintenance, chemical treatment, repairs and accidents are time consuming and costly in terms of equipment and production costs.
Conventional chemical treatment:
In some places, such as cooling towers and hot water circuits, it is important that the water has a certain degree of hardness to prevent corrosion. Therefore, water hardness stabilizers are used, and just as often completely softened water is mixed again with untreated water. In addition, ion exchange resins suggest an expensive and complex way to treat water, which can often enhance the corrosive properties of water and create problems.


PROTECTS YOUR WHOLE HOME FROM BOILER AND DEPOSITS, PROTECTS THE WATER SUPPLY AS WELL AS ALL VESSELS FOR USE

Principle of HMS operation
Principle of HMS operation - magnetic interaction of ions present in water (magnetic resonance) and simultaneous chemical crystallization process.
Ferromagnetic particles dissolved in water under the action of strong
magnetic field, become centers of electrochemical crystallization, connecting the ions of calcium and magnesium, which form the basis of water hardness. The operation of the water hardness neutralizer - HMS - is based on
cyclic effect on water of a magnetic field with a certain
spatial configuration created by high-energy magnets of the Nd-Fe-B type. Structurally HMS consists of a housing based on magnetic material, serving as a magnetic conductor, completely isolating the magnetic field inside the product and a magnetic system - core. The magnetic core consists of a thin-walled stainless steel tube, inside which are located in a certain order and orientation permanent magnets and pole elements. At the end of the pipe there are conical nozzles, providing laminar flow of water inside the neutralizer. Centering elements ensure a constant position of the core
regarding the housing of the device. Structurally, the magnetic system is reliably isolated from direct contact with water, and the tips and centering elements are made of stainless steel. The use of high-energy magnets retaining their properties for a very long time (49 years or more) and stainless steel elements allows to achieve a very long service life. The cross section of the HMS between the housing and the core ensures unchanged pressure and water flow at the inlet and outlet pipeline.
Magnet parameters:
Nd-R-Fe-Co-Ti-Cu-B
Residual induction / T: 1.2 - 1.3
Coercive force of magnetization / kA / m: 1 600-2 400
Magnetic energy / kD / m3: 280 - 320

Under the influence of the magnetic field in the working volume, the physical properties of the water flowing through the hardness neutralizer change and the silicates, magnesium and calcium salts contained in it lose their ability to form a dense scale and leak (especially after heating). in the form of sludge, with the flow of water. The water treated with the neutralizer breaks and separates the already formed and previously deposited on the walls of the aquifers old scale and prevents the formation of new ones. The optimal range of water velocity in the water hardness converter is 0.5 - 4.0 m / second. Magnetic water treatment does not require any chemical reagents and therefore this method is absolutely environmentally friendly.
 

View product 200,00

HYDRO MAGNETIC SYSTEM Ф15 2.0М3 / Ч

Send an enquiry
View product 97,44

HYDRO MAGNETIC SYSTEM Ф15м 0,8М3 / Ч

Send an enquiry
View product 100,00

HYDRO MAGNETIC SYSTEM Ф20м 0.8М3 / Ч

Send an enquiry